  1. Readme Version 1.0c
  2.  
  3.     This firmware is for CRW6416S.
  4.  
  5.     * DO NOT USE THIS FIRMWARE FOR OTHER DEVICES.
  6.     * DO NOT USE THIS UTILITY PROGRAM TO INSTALL OTHER VERSIONS OF THE FIRMWARE.
  7.  
  8.     Before upgrading the firmware:
  9.         1, Check the SCSI ID number of the Yamaha recorder and 
  10.         the SCSI Card number.  Look at the CD Recorder Property 
  11.         in the mastering software. 
  12.  
  13.         2, Disconnect all other SCSI devices if they are connected 
  14.         to the same computer. 
  15.  
  16.     1)  This folder contains three files as stated below.
  17.  
  18.     1, Scb99826.bin          Updated Version 1.0c
  19.  
  20.     2, Scinst.exe          Installer program to execute firmware upgrade
  21.                   (for DOS version) Version 1.13
  22.  
  23.     3, ScREADME.txt          Instruction for the upgrade
  24.  
  25.     2) How to install the new firmware.
  26.       Connect the recorder to the host PC via SCSI I/F.
  27.       Turn the recorder on (no disc in the drive).
  28.         Turn on the host PC and start the MS-DOS Prompt from Windows 95/98.
  29.  
  30.     3)These two files should be put in the same folder.
  31.  
  32.     1, Scb99826.bin
  33.  
  34.     2, Scinst.exe
  35.  
  36.     COMMAND
  37.          Type in:
  38.     scinst scb99826.bin 3 0
  39.      
  40.     usage......scinst [Fn][ID][Scnum]
  41.         [File name]    Scb99826.bin  (new firmware file)
  42.         
  43.         [CRW6416S SCSI ID] 3  if there is only one device connected
  44.         Although the Default setting is "3" it can be changed to any numbers 
  45.         from 0 through 6 if more than one SCSI devices are connected. 
  46.  
  47.         [SCSI Card number] 0  if there is only one SCSI board being used
  48.         Although the Default setting is "0" it can be changed to any numbers
  49.         from 1 through 7.  The system may automatically change SCSI Card number 
  50.         when a new device is added.  Check with the SCSI Card number 
  51.         in the "CD-R Properties" of the mastering software.
  52.    
  53.  
  54.  
  55.     CRW6416S receives the binary data from the PC via SCSI line
  56.     to be stored into internal buffer in the drive.
  57.     
  58.     If error occurs, "SCSI I/O error occurred" will appear.
  59.     If you have any troubles, please check with the connection
  60.     or selected SCSI ID conflict or AC power supply or anything else
  61.     that may be causing the error.
  62.  
  63.     CRW4416S starts the binary data copy from internal buffer to its
  64.     flash memory after all data is received from the PC.
  65.     ON/DISC LED and READ/WRITE LED on the front panel will
  66.     blink during the process.
  67.     When it finishes, DISC/ON LED becomes
  68.     solid orange and READ/WRITE LED will be turned off.
  69.     After that, power down the CRW drive to reset the system.
  70.  
  71.     You can check the firmware version number with the
  72.     INQUIRY command or by rebooting the PC and the CRW.
  73.     If the installment is completed properly, MSCDEX can mount
  74.     CRW6416S using a generic CD-ROM device driver.
  75.     The device type of CRW6416S is "5".
  76.     Therefore a generic CD-ROM device driver can be used for this drive.
  77.     
  78.  
  79.     3)How to get the new firmware.
  80.     This http site
  81.     http://www.yamaha.co.jp/english/product/computer/